168 TimeProvider 2300/2700 User’s Guide 098-00564-000 Revision A3 – July, 2013
Chapter 3
TimeProvider 2300/2700 CLI Command Set
Command Syntax:
To set the SyncE state for the specified PTP/SyncE port:
set synce state {eth1 | eth2} {enable | disable}
To set the SyncE QL state:
set synce ql-state eth2 {enable | disable}
Example 1:
To enable SyncE for the ETH2 port:
TP2700> set synce state eth2 enable
Example 2:
To disable QL-state for ETH2 port:
TP2700> set synce ql-state eth2 disable
Remarks: This command only applies to PTP/SyncE ports.
Level : Config and Admin
Note: SyncE direction is not user-configurable for the initial release.
The ETH1 port is a SyncE Input, and ETH2 is a SyncE Output.