5.2 Block Execution
After the word is input, is pressed and the display is as follows:
After the code words are input and is pressed to display the block, key is pressed
to execute the input block. During the execution, , and Emergency Stop button may be
pressed to terminate these code words execution.
Note: The subprogram call codes (M98 P_ etc.), compound cutting cycle codes(G70, G71, G72,
G73, G12.1,
G7.1 and so on) is inactive in MDI mode.
5.3 Parameter Setting
In MDI mode, the parameter value can be altered after entering the parameter interface.
The
222
Operation
detailed is referred to OPERATION, Chapter 10.
5.4 Data Alteration
In PRG->MDI page, if there is an error during words inputting before executing the input
block,
is pressed to cancel the display to alter the program, or is pressed to clear all the
input, then correct re-inputting is executed.
5.5 Other Operations
1. Adjusting spindle override
In MDI mode, the spindle speed can be adjusted when the analog voltage output controls
the
spindle speed.
Pressing , can adjust the spindle override to change the spindle speed, which can
realize the 8 steps adjustment in real-time from 50%~120.
2.Adjusting rapid override
Pressing can execute the rapid traverse, which can realize the 4 steps
adjustment in real-time.
3. Adjusting feedrate
In MDI mode, pressing , , can adjust the federate override to change the
federate, which can realize 16 steps adjustment from 0150.
4. Feedrate override is available.
Chapter 6 Program Edit and Management
223
Operation
CHAPTER 6 PROGRAM EDIT AND MANAGEMENT
In Edit mode, a program can be created, selected, altered, copied and deleted, and the