EasyManua.ls Logo

TOMATECH TAC-100XT - Pitch Error Compensation Number; Pitch Error Compensation Interval; Offset Value

TOMATECH TAC-100XT
415 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TOMATECH AUTOMATION
6.3.2 Pitch error compensation number
Set the maximum pitch error compensation number and the minimum pitch error
compensation
number of each axis through parameters No.096 and No.097 so that the compensation
range can be
determined. In an offset value list, the number that corresponds to machine zero point is
called pitch
error compensation origin (reference point). The pitch error compensation origin is set by
parameter
No. 098. It can be any value within the compensation range according to mechanical
requirement.
Data parameter
0 9 6 PECMINn
The maximum pitch error compensation number
0 9 7 PECMAXn
The minimum pitch error compensation number
0 9 8 PECORGn
The pitch error compensation number that corresponds to machine zero point
Chapter 6 Memorizing Pitch Error
447
Connection
6.3.3 Pitch error compensation interval
0 9 9 PECINTn
Meaning Interval between pitch error compensation point
Unit
Setting Unit IS-B IS-C
Metric machine 0.001 mm 0.0001 mm
Inch machine 0.0001 inch 0.00001 inch
Range
IS-B IS-C
Metric machine 1000999999 100009999999
Inch machine 400999999 40009999999
6.3.4 Offset value
Pitch error offset amount of each axis is set according to the following table, and offset
amount is
input in diameter value without relating to diameter programming or radius programming,
and the
input value unit is the least input increment.
Offset No. Offset value Z Offset value
000 0 0200 0
001 5 0201 -2
002 -3 0202 4
… … … …
… … … …