Command function: After M00 is executed, the program stops and the system displays
“Pause”,
and then the program continuously runs after the cycle start key is pressed.
Program optional stop M01
Command format: M01 or M1
26
Ⅰ Programming
Command function: in AUTO, MDI mode, it is valid. Press and its indicator lights and the
system enters the optional stop state, at the moment, the program stops run
and the system displays “PAUSE” after M01 is executed, after the cycle start
key is pressed, the program continuously runs. When the program optional
stop switch is not open, the program does not pause even if M01 runs.
Spindle CW, CCW and stop control M03, M04, M05
Command format: M03 or M3
M04 or M4;
M05 or M5.
Command function: M03: Spindle CW rotation;
M04: Spindle CCW rotation;
M05: Spindle stop.
Note: Refer to time sequence of output defined by standard PLC ladder in Ⅲ INSTALLATION &
CONNECTION.
Cooling control M08, M09
Command format: M08 or M8;
M09 or M9;
Command function: M08: Cooling ON;
M09: Cooling OFF.
Note: Refer to time sequence and logic of M08, M09 defined by standard PLC ladder in Ⅲ
INSTALLATION & CONNECTION.
Tailstock control M10, M11
Command format: M10;
M11;
Command function: M10: tailstock going forward;
M11: tailstock going backward.
Note: Refer to time sequence and logic of M10, M11 defined by standard PLC ladder in Ⅲ
INSTALLATION & CONNECTION
Chuck control M12, M13
Command format: M12;
M13;
Command function: M12: chuck clamping;
M13: chuck releasing.
Note: Refer to time sequence and logic of M12, M13 defined by standard PLC ladder in Ⅲ
INSTALLATION & CONNECTION.
Spindle position/speed control switch M14, M15