TOMATECH AUTOMATION
[Data meaning] Acceleration/deceleration time constant during cutting feed and manual
feed
[Data unit] ms
[Data range] 0~4000
0 3 0 FEDFL
[Data meaning] The starting speed of cutting feed
[Data unit]
Setting unit Data unit
Metric machine mm/min
Inch machine 0.1inch/min
[Data range]
IS-B IS-C
Metric machine 0~8000 0~8000
Inch machine 0~3000 0~3000
0 3 1 JOGSPEED
[Data meaning] Set speed when manual feedrate override is 100%
[Data unit]
Setting unit Data unit
Metric machine mm/min
Inch machine 0.1inch/min
[Data range] 10~30000
0 3 2 RPDFLn
[Data type] Word axis
[Data meaning] The rapid traverse rate when the override is F0
[Data unit]
Setting unit Data unit
Metric machine mm/min
Inch machine 0.1inch/min
[Data range]
IS-B IS-C
400
Volume Ⅲ Connection
Metric machine 0~4000 0~4000
Inch machine 0~1500 0~1500
3.2.3 Precision compensation
0 0 3 PEC
Bit5 1: Pitch error offset active
0: Pitch error offset inactive
0 1 0 *** *** *** CPF5 CPF4 CPF3 CPF2 CPF1
CPF4~CPF1: Setting values of backlash offset pulse frequency (by BCD code)
The set frequency =(setting value+1) Kpps
CPF5 CPF4 CPF3 CPF2 CPF1 Set frequency(Kpps)
0 0 0 0 0 1