TOMATECH AUTOMATION
2.8.20 External override
� Related signals
Type Sign Interface Address Function Remark
OV1 CN61.8 X0.7 External override 1
OV2 CN61.9 X1.0 External override 2
OV3 CN61.10 X1.1 External override 3
Input
signal
OV4 CN61.11 X1.2 External override 4
The external
feedrate override
switch and the tool
signals T5~T8
are multiplexed
� Related parameters
PLC state parameter
K 1 6 ROVI SOVI
ROVI =0: External feedrate override does not inverse.
=1: External feedrate override inverses.
SOVI =0: External feedrate override switch is disabled.
=1: External feedrate override switch is enabled.
� Function description
1. When the external feedrate override switch is selected, the button on the panel is
disabled.
2. When the external feedrate override switch and the tool signal T5~T8 are multiplexed,
and
Yantai, Liuxin Tool Post is selected or the total tool count is more than 4, the external
feedrate
override cannot be selected.
3. When the external feedrate override inverses, the system changes the direction of the
override regulation.
2.8.21 External MPG
� Related signals
CN31(MPG)
PLC
address
Address
character
Function Remark
5 X6.0 EHDX X MPG
6 X6.1 EHDY Y MPG
8 X6.2 EHDZ Z MPG
Applied
toPSG-100-05E/L,