TOMATECH AUTOMATION
A0002.1 1016 Alarm of safe door not closed
A0002.3 1017 Alarm of chuck low pressure
A0002.4 1019 Chuck released unallowed in spindle running
A0002.5 1020 Clamping in-position signal inactive alarm in spindle running
A0002.6 1021
Spindle start unallowed if chuck clamping in-position signal
inactive
A0003.0 1022 Spindle start unallowed for chuck releasing
A0003.0 1024 M12/M13 code disabled as chuck inactive
A0003.1 1025 Has not checked the chuck clamped/released start signal
A0003.3 1027 The tool pot is not released
A0003.4 1028 Has not found the target tool
A0003.5 1029 Has not received tool pot stop and locking start signal
A0003.7 1031
Total tools is more than 4, and the external override cannot be
connected
A0004.1 1032 Illegal M code
A0004.2 1033 Spindle jog disabled in non-analog spindle mode
A0004.3 1035 M63, M64 designation error
A0004.4 1036 Spindle gear change time is too long
A0004.5 1037 Spindle speed/position control switch time is too long
A0004.6 1038 The 2nd spindle speed/position control switch time is too long
A0004.7 1039 Spindle position control does not permit the orientation
A0005.0 1040 Spindle orientation time is too long
A0005.1 1041 Alarm for the abnormal spindle servo or frequency converter for
abnormality
A0005.2 1042 Alarm for the abnormal 2nd spindle servo or frequency converter
A0005.3 1043 Forbid clamping the spindle when the spindle rotating or feeding
Chapter 5 Diagnosis Message
441
Connection
Address Alarm No. Content
A0005.4 1044 Spindle is clamped not to rotate or feed
A0007.0 2000 Hydraulic motor is not started
A0007.1 2001 Safety door has been opened
A0007.3 2003 Alarm for the tool pot unclocked
5.2.7 K addressK parameter, standard PLC definition
RRW =1: the cursor returning to the head of the program in any working modes when the
system resets is valid;
=0: the cursor returning to the head of the program in edit mode when the system resets is
valid
RSJG =1: the spindle lubricating, cooling output keep when the system resets;
=0: the spindle lubricating, cooling output close when the system resets.
OUTR =1: pressing can start the program run in MDI mode;