EasyManua.ls Logo

TOMATECH TAC-100XT - Input and Output Function in Metric and Inch System; Parameters Related to Arc Turning; Parameters Related to the Additional

TOMATECH TAC-100XT
415 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TOMATECH AUTOMATION
Data meaning XAUTO_OFFSET_Y_X,ZAUTO_OFFSET_Y_Zγ value in
automatic tool
offset.
Data unit
Set unit IS-B IS-C
Metric machine 0.001 mm 0.0001 mm
Inch machine 0.0001 inch 0.00001 inch
Data range 19999999
Note: X setting value is the radius in diameter programming and radius programming.
1 4 4 AUTO_OFFSET_E_X
1 4 5 AUTO_OFFSET_E_Z
Data meaning AUTO_OFFSET_E_XX,AUTO_OFFSET_E_ZZε value in
automatic tool
offset.
Note: The function needs the automatic tool setting device.
3.2.17 Input and output function in metric and inch system
0 0 1 *** *** INI
INI 1: Inch input
0: Metric input
0 0 3 *** *** *** *** *** OIM
OIM 1: Offset automatically change in metric and inch conversion
0: Offset not change in metric and inch conversion
0 0 4 *** SCW
SCW 1: Inch system for min. code unit, active after repowering
0: Metric system for min. code unit, active after repowering
3.2.18 Parameters related to arc turning
1 5 4 RADIUS_ERR_RANGE
Data meaning max. value of arc radius error.
Data unit
Setting unit IS-B IS-C
Metric machine 0.001 mm 0.0001 mm
Chapter 3 Parameters
413
Volume Connection
Inch machine 0.0001 inch 0.00001 inch
Data range
IS-B IS-C
Metric machine 01000 010000
Inch machine 050 0500
3.2.19 Parameters related to the additional
1 8 7 IS1 IS0 RCS *** *** *** ROS ROT
[Data type]: Bit axis
BIT7,BIT6: set incremental system of each axis00: consistent with the incremental
system of the

Table of Contents