TOMATECH AUTOMATION
valid.
K 1 7 MSEN SCLP SALM2 SALM SSTP *** *** ***
SSTP =0: do not close the analog voltage when the spindle stops;
=1: close the analog voltage when the spindle stops.
SALM =0: the alarm occurs when the spindle HIGH;
=1: the alarm occurs when the spindle HIGH.
SALM2=0: the occurs when the 2nd spindle HIGH;
=1: the occurs when the 2nd spindle LOW.
SCLP =0: the spindle clamping commands executes the 1st spindle clamped, the
multi-spindle
function is valid;
=1: the spindle clamping commands executes the 2nd spindle clamped, the multi-spindle
function is valid;
MSEN =0: the multi-spindle control function is invalid;
=1: the multi-spindle control function is invalid.
K 1 8 *** *** *** *** MDOK MD4 MD2 MD1
MDOK =0: the operation mode when power-on again is the one that the system is turned
off;
=1: the operation mode when power-on is the one specified by MD4, MD2, MD1.
MD4 MD2 MD1 Operation mode when power on
0 0 0 MDI mode
0 0 1 Auto mode
0 1 0 Program zero return
0 1 1 Edit mode
1 0 0 MPG mode
1 0 1 Manual mode
1 1 0 Machine zero return
5.3 PLC Data
5.3.1 Timer address T(defined by standard PLC ladders)
Address Meaning
444
Ⅲ Connection
T0000 Timing the closing previous gear count
T0001 Timing from New gear outputting to FIN
T0002 M3, 4, 5, 8, 9, 10, 11, 32, 33 execution timing
T0004 timing from tool CCW stop to CW start
T0005 timing for tool CW
T0006 S code execution timing
T0007 M01, 02, 30 execution timing
T0008 Having not received alarm time of TCP signal
T0009 Tool rotation(CW) timing
T0010 Timing from the spindle stop to brake output