5th grade 3 digits 123
6th grade None None
Note 2: When the operation level is less than or equal to the 3rd grade ( 3rd, 4th, 5th or 6th grade) and
the
system is turned on again, the operation level does not change. When the level is the 2nd grade
and the
system is turned on again, the operation level defaults to the 3rd grade.
2) Password modification
Steps:
a) The operator enters the grade to alter the password according to the method
“Operation
grade entry” after the system enters the setting page;
b) Move the cursor to the line “ALATER PASSWORD”;
Chapter 10 Data Setting, Backup and Restore
269
Operation
c) Input the new password, and then press ;
d) The CNC prompts “ Input the new password again”;
e) Input the new password again and then press . When the two input passwords
are identical, the CNC prompts “Password has been altered, please save the new
password.” The password alteration is done successfully.
Note: The system prompts “ The new password is not identical with the confirmation” when the
two
input passwords are not identical. At the moment, input the new password again.
3) Operation grade degradation
The degradation is to degrade from the high to the low, and its steps are shown below:
a) Input the password according the method of “Operation grade entry” after the system
enters the setting page;
b) Move the cursor to the line “CURRENT LEVEL” and the system pops up
as follows:
c) Press or , and the CNC prompts “Password degrades one grade”
as follows:
270
Operation
d) Press or again, and the degradation is done successfully as
follows:
Note 1: The degradation operation cannot be executed when the current level is the 6th grade.
Note 2: The current password can be altered after degradation. When the system is in the high
level, the
degradation can be executed to set to the low-level password.
10.1.3 Parameter operation
The parameter data (state parameter, data parameter) can be backup (stored) and