TOMATECH AUTOMATION
NT14: Current tool No. NT14
NT15: Current tool No. NT15
G0203 NT23 NT22 NT21 NT20 NT19 NT18 NT17 NT16
NT16: Current tool No. NT16
NT17: Current tool No. NT17
NT18: Current tool No. NT18
NT19: Current tool No. NT19
NT20: Current tool No. NT20
NT21: Current tool No. NT21
NT22: Current tool No. NT22
NT23: Current tool No. NT23
G0204 NT31 NT30 NT29 NT28 NT27 NT26 NT25 NT24
NT24: Current tool No. NT24
NT25: Current tool No. NT25
NT26: Current tool No. NT26
NT27: Current tool No. NT27
NT28: Current tool No. NT28
NT29: Current tool No. NT29
NT30: Current tool No. NT30
NT31: Current tool No. NT31
440
Ⅲ Connection
5.2.6 Address A (message display requiery signal, defined by standard
PLC
ladders)
Address Alarm No. Content
A0000.0 1000 Tool change too long
A0000.1 1001 Tool post not in-position alarm as tool change ends
A0000.2 1002 Tool change unfinished alarm
A0000.3 1003 Tool post clamping signal not received
A0000.4 1004
Recheck clamping signal, and clamping signal inactive as tool
change ends
A0000.5 1005 Tool change execution is mistaken before power off
A0000.6 1006 Pre-indexing proximity switch not arrived
A0000.7 1007 Tool post overheat alarm
A0001.0 1008 M10 and M11 codes disabled for tailstock function inactive
A0001.1 1009 Run-out disabled in spindle running
A0001.3 1011 Spindle start unallowed as tailstock advancing not detected
A0001.4 1012 Cycle unallowed for cycle start disabled
A0001.5 1013 Spindle start unallowed for spindle enable off
A0001.6 1014 Confirm the tools of tool post (8, 10, 12 tools)
A0002.0 1014 Please reset BIT1, BIT0 of parameter 168 for tool post model