EasyManuals Logo

TOMATECH TAC-100XT User Manual

TOMATECH TAC-100XT
415 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #339 background imageLoading...
Page #339 background image
TOMATECH AUTOMATION
Data unit
Set unit IS-B IS-C
Metric machine 0.001 mm 0.0001 mm
Inch machine 0.0001 inch 0.00001 inch
Data range 2000 20000
Data range 02000
Note: X is diameter value.
0 9 6 PECMINn
Data type Word axis
Data meaning Minimum pitch error compensation number
Data range 01023
0 9 7 PECMAXn
Data type Word axis
Data meaning Maximum pitch error compensation number
Data range 01023
0 9 8 PECORGn
Data type Word axis
Data meaning Pitch error compensation number corresponding to machine zero
Data range 01023
0 9 9 PECINTn
Data type Word axis
Data meaning Pitch error compensation intervals
Data unit
Setting unit IS-B IS-C
Metric machine 0.001 mm 0.0001 mm
402
Volume Connection
Inch machine 0.0001 inch 0.00001 inch
Data range
IS-B IS-C
Metric machine 1000999999 100009999999
Inch machine 400999999 40009999999
3.2.4 Machine protection
1 7 2 *** MST MSP MOT ESP *** LZR ***
Bit6 1: External cycle start signal (ST) inactive, it is not the cycle start switch and can be
defined by
macro code (#1014)
0: External cycle start signal (ST) active.
Bit5 1: External SP signal inactive, and it is not the dwell switch and can be defined by
macro code.
( #1015)
0: External SP signal active with external dwell switch connected, otherwise CNC shows
“stop”.mailto:M@SP=1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TOMATECH TAC-100XT and is the answer not in the manual?

TOMATECH TAC-100XT Specifications

General IconGeneral
BrandTOMATECH
ModelTAC-100XT
CategoryControl Systems
LanguageEnglish