[Data unit]
Set unit IS-B IS-C
Metric machine 0.001 mm 0.0001 mm
Inch machine 0.0001 inch 0.00001 inch
Data range 2000 20000
[Data range] 0~2000
Note: X is diameter value.
0 9 6 PECMINn
[Data type] Word axis
[Data meaning] Minimum pitch error compensation number
[Data range] 0~1023
0 9 7 PECMAXn
[Data type] Word axis
[Data meaning] Maximum pitch error compensation number
[Data range] 0~1023
0 9 8 PECORGn
[Data type] Word axis
[Data meaning] Pitch error compensation number corresponding to machine zero
[Data range] 0~1023
0 9 9 PECINTn
[Data type] Word axis
[Data meaning] Pitch error compensation intervals
[Data unit]
Setting unit IS-B IS-C
Metric machine 0.001 mm 0.0001 mm
402
Volume Ⅲ Connection
Inch machine 0.0001 inch 0.00001 inch
[Data range]
IS-B IS-C
Metric machine 1000~999999 10000~9999999
Inch machine 400~999999 4000~9999999
3.2.4 Machine protection
1 7 2 *** MST MSP MOT ESP *** LZR ***
Bit6 1: External cycle start signal (ST) inactive, it is not the cycle start switch and can be
defined by
macro code (#1014);
0: External cycle start signal (ST) active.
Bit5 1: External SP signal inactive, and it is not the dwell switch and can be defined by
macro code.
( #1015);
0: External SP signal active with external dwell switch connected, otherwise CNC shows
“stop”.mailto:M@SP=1