DT018 Chuck pulse output width (ms) (can be modified directly)
DT020 Spindle clamping/unclamping time (ms)
DT021 Spindle stop, chuck enable delay time (ms)
DT023 Delay time before spindle motor torque decreases to 0 after
spindle starts clamping
5.3.4 Counter presetting address DC
Address Meaning
DC000 Spindle zero-speed output range (r/min)
446
Connection
CHAPTER 6 MEMORIZING PITCH ERROR
COMPENSATION
6.1 Function Description
There are more or less precision errors in the pitch of machine axes lead screw, and it will
definitely affect the parts machining precision. ThisTAC-1002T CNC system has the
memorizing
pitch error offset function that it can accurately compensate the pitch error of the lead
screw.
6.2 Specification
1) The set offset amount is concerned with the offset origin, offset intervals etc.;
2) Pitch error offset value is get by searching the table about machine coordinates and
pitch
error compensation origin;
3) Points to be compensated: 1024 points for 5 axes, each axis confirms point range by
parameter setting;
4) Axis compensated: X, Y, Z ,4th,5th axis
5) Compensation range: -25502550×least input increment;
6) Compensation interval: 100009999999××least input increment;
7) Compensation amount of compensation point N(N=0,1,2,3,…1023) is determined by
the
mechanical error between point N and point N-1;
8) The setting is the same as the CNC parameters input, see Operation.
6.3 Parameter Setting
6.3.1 Pitch compensation
Bit parameter
0 0 3 PCOMP
Bit5=1: Pitch error offset active;
Bit5=0: Pitch error offset inactive;