TOMATECH AUTOMATION
position
422
Ⅲ Connection
longer delay may damage the motor, shorter delay may cause the tool post not to be
completely
clamped. The method to check the tool post clamping is: approach the dial-indicator to the
tool post,
turn the tool post manually, and the pointer floating of the dial-indicator should not be over
0.01mm.
The BIT7(TL-) and BIT6(TL+) of diagnosis message DGN.005 are used to check the
validity of
tool post CCW/CW output signal.
The BIT0~BIT3 (T01~T04) of diagnosis message DGN.000 are used to check the
validity of
tool number T01~T04 signal.
During debugging, every tool, max. tools change should be performed to check the
correctness
of the tool change, time parameter setting.
4.9 Step/MPG Adjustment
The key on the panel can be used to select the Step mode or MPG mode, which is set by
the BIT3 of bit parameter No.001.
Bit3 =1: MPG mode active, Step mode inactive;
=0: Step mode active, MPG mode inactive;
Chapter 5 Diagnosis Message
423
Ⅲ Connection
CHAPTER 5 DIAGNOSIS MESSAGE
Diagnosis messages forTAC-1002T system are described in this chapter.
5.1 CNC Diagnosis
The part is used to check the CNC interface signals and internal running and it can’t be
modified.
5.1.1 I/O status and data diagnosis message
0 0 0 ESP *** *** DEC5 DEC4 DECZ DECY DECX
Pin CN61.6 CN61.34 CN61.33 CN61.12 CN61.32 CN61.4
PLC fixed
address
X0.5 X2.5 X2.4 X1.3 X2.3 X0.3
DECX, DECY, DECZ, DEC4, DEC5: machine zero return signal of X, Y, Z, 4th, 5th
ESP: emergency stop signal
0 0 1 *** *** *** *** *** *** *** SKIP