Fig. 3-24
3.19.3 Caution of fixed cycle commands
1) After X(U) , Z(W) , R are executed in the canned cycle command, their command
values are value if X(U) , Z(W) ,R are not redefined by executing a new canned cycle
commands. The command values of X(U) ,Z(W) ,R are cleared if non-modal G
command(00 Group) except for G04 or G00,G01, G02, G03, G32 is executed.
2) In MDI mode, the previous canned cycle can be executed by pressing the cycle start
key after the canned cycle is completed.
3) One cycle cannot be executed repetitively in G90~G94 when the next block of G90~
G94 is M, S, T command; the previous cycle is executed repetitively in G90~G94 when
the next block is ended( EOB;).