EasyManua.ls Logo

TOMATECH TAC-100XT - Communication Setting

TOMATECH TAC-100XT
415 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TOMATECH AUTOMATION
0: Cursor to beginning by pressing CYCLE START key after M30
0 1 2 ALM&
PRG
Bit3 1: Program editing allowed during CNC alarming
0: Program editing unallowed during CNC alarming
1 8 0 SPOS
Bit0 =1: DIS TO GO displayed in POS&PRG page
=0: RELATIVE POS displayed in POS&PRG page
1 8 4 *** PTEST *** *** *** L2 L1 L0
Bit0, Bit1, Bit2: Interface language selection
Language Bit2 Bit1 Bit0
Chinese 0 0 0
English 0 0 1
Portugal 0 1 0
Spanish 0 1 1
Russian 1 1 0
3.2.12 Communication setting
0 4 4 BRATE0
Data meaning baud rate of serial communication.
Data unit bit/s
Data range 1200,2400,4800,9600,19200,38400,57600 ,115200
3.2.13 MPG Parameters
0 0 1 *** *** MPG
Bit3 1: MPG mode
0: Step mode
0 1 3 *** *** *** HW5 HW4 HWY HWZ HWX
Bit4 1: coordinates increase when 5th MPG rotates CCW;
0: coordinates increase when 5th MPG rotates CW.
Bit3 1: coordinates increase when 4th MPG rotates CCW
0: coordinates increase when 4th MPG rotates CW.
Bit2 1: coordinates increase when Y MPG rotates CCW
0: coordinates increase when Y MPG rotates CW.
Chapter 3 Parameters
411
Volume Connection
Bit1 1: coordinates increase when Z MPG rotates CCW
0: coordinates increase when Z MPG rotates CW.
Bit0 1: coordinates increase when X MPG rotates CCW
0: coordinates increase when X MPG rotates CW.
K 1 6 SINC SINC2 *** *** *** *** *** ***
Bit7 1: In STEP(MPG) mode and when the system increment is 0.1u, ×1000 gear is
invalid
0: In STEP(MPG) mode and when the system increment is 0.1u, ×1000 gear is valid
Bit6 1: In STEP(MPG) mode and when the system increment is 1u, ×1000 gear is invalid

Table of Contents