1 8 7 IS1 IS0
[Data type]: Bit axis
BIT7, BIT6set increment system of each axis. 00accordance with increment system of
the
system; 01IS-A10IS-B11IS-C.
2 0 3 *** *** *** ABP5 ABP4 ABPY ABPZ ABPX
Bit4 1: 5th pulse outputs according to the two-phase quadradure (need to power-on again);
0: 5th pulse outputs according to (pulse + direction) (need to power-on again).
Bit3 1: 4th pulse outputs according to the two-phase quadradure (need to power-on again);
0: 4th pulse outputs according to (pulse + direction) (need to power-on again).
Bit2 1: Y pulse outputs according to the two-phase quadradure (need to power-on again);
0: Y pulse outputs according to (pulse + direction) (need to power-on again).
Bit1 1: Z pulse outputs according to the two-phase quadradure (need to power-on again);
0: Z pulse outputs according to (pulse + direction) (need to power-on again).
Bit0 1: X pulse outputs according to the two-phase quadradure (need to power-on again);
0: X pulse outputs according to (pulse + direction) (need to power-on again).
3.2.2 Acceleration & deceleration control
0 2 2 RPDFn
Data type Word axis
Data meaning max. speed of X rapid traverse (radius value)
Data unit
Setting unit Data unit
Metric machine mm/min
Inch machine 0.1inch/min
Data range 1099999999
0 2 3 LINTn
Data type Word axis
Data meaningAcceleration/deceleration time constant value
Data unit ms
Data range 104000
0 2 7 FEDM
Data meaning Upper limit of cutting feedrate
Data unit
Setting unit Data unit
Chapter 3 Parameters
399
Volume Connection
Metric machine mm/min
Inch machine 0.1inch/min
Data range
IS-B IS-C
Metric machine 1015000 1015000
Inch machine 55800 105800
0 2 9 FEEDT