TOMATECH AUTOMATION
1 8 7 IS1 IS0
[Data type]: Bit axis
BIT7, BIT6:set increment system of each axis. 00:accordance with increment system of
the
system; 01:IS-A,10:IS-B;11:IS-C.
2 0 3 *** *** *** ABP5 ABP4 ABPY ABPZ ABPX
Bit4 1: 5th pulse outputs according to the two-phase quadradure (need to power-on again);
0: 5th pulse outputs according to (pulse + direction) (need to power-on again).
Bit3 1: 4th pulse outputs according to the two-phase quadradure (need to power-on again);
0: 4th pulse outputs according to (pulse + direction) (need to power-on again).
Bit2 1: Y pulse outputs according to the two-phase quadradure (need to power-on again);
0: Y pulse outputs according to (pulse + direction) (need to power-on again).
Bit1 1: Z pulse outputs according to the two-phase quadradure (need to power-on again);
0: Z pulse outputs according to (pulse + direction) (need to power-on again).
Bit0 1: X pulse outputs according to the two-phase quadradure (need to power-on again);
0: X pulse outputs according to (pulse + direction) (need to power-on again).
3.2.2 Acceleration & deceleration control
0 2 2 RPDFn
[Data type] Word axis
[Data meaning] max. speed of X rapid traverse (radius value)
[Data unit]
Setting unit Data unit
Metric machine mm/min
Inch machine 0.1inch/min
[Data range] 10~99999999
0 2 3 LINTn
[Data type] Word axis
[Data meaning]Acceleration/deceleration time constant value
[Data unit] ms
[Data range] 10~4000
0 2 7 FEDM
[Data meaning] Upper limit of cutting feedrate
[Data unit]
Setting unit Data unit
Chapter 3 Parameters
399
Volume Ⅲ Connection
Metric machine mm/min
Inch machine 0.1inch/min
[Data range]
IS-B IS-C
Metric machine 10~15000 10~15000
Inch machine 5~5800 10~5800
0 2 9 FEEDT