EasyManua.ls Logo

TOMATECH TAC-100XT - G Address (PLC→CNC)

TOMATECH TAC-100XT
415 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TOMATECH AUTOMATION
CINP: G04 code being executed
CDWL: RS232 interface being receiving
F0213 *** *** *** *** *** *** CTRD CTPU
CTRD: RS232 interface being transmitting
CTPU: Spindle jog/lubricating selection
F0214 *** *** *** VAL5 VAL4 VALY ZVAL XVAL
VAL5: 5th axis direction selection
VAL4: 4th axis direction selection
VALY: Y direction selection
VALZ: Z direction selection
VALX: X direction selection
5.2.5 G address (PLC→CNC)
G0004 *** *** *** *** FIN *** *** ***
FIN: MST function end signal
G0005 *** AFL *** *** *** *** *** ***
AFL: MST lock signal
SFIN: Spindle S function end signal
G0006 *** SKIPP *** OVC *** ABSM *** SRN
OVC: Feedrate override cancel signal
SRN: Program restart signal
G0007 RLSOT EXLM *** *** *** ST STLK ***
ST: Cycle start signal
436
Connection
G0008 ERS RRW SP ESP *** *** *** IT
ERS: External reset signal
RRW: Reset and cursor return signal
SP: Feed hold signal
ESP: Emergency stop signal
G0010 JV07 JV06 JV05 JV04 JV03 JV02 JV01 JV00
G0011 JV15 JV14 JV13 JV12 JV11 JV10 JV09 JV08
JOG override signal JV00~JV15
G0012 FV07 FV06 FV05 FV04 FV03 FV02 FV01 FV00
Feedrate override signal FV00~FV07
G0014 *** *** *** *** *** *** RV2 RV1
RV2: Rapid feedrate override signal RV2
RV1: Rapid feedrate override signal RV1
G0018 *** *** *** *** HD HC HB HA
HD: MPG feed selection signal (01004th)
HC MPG feed selection signal (01015th)
HB: MPG feed selection signal (0011Y)
HA: MPG feed selection signal (0001X. 0010Z)
G0019 RT *** MP2 MP1 *** *** *** ***

Table of Contents