TOMATECH AUTOMATION
Inch input 0.0001 inch 0.00001 inch
[Data range]
IS-B IS-C
Metric input -99999~99999 -999999~999999
Inch input -99999~99999 -999999~999999
1 2 0 REF1_COORDn
1 2 1 REF2_COORDn
1 2 2 REF3_COORDn
1 2 3 REF4_COORDn
[Data type] Word axis
[Data meaning]REF1_COORDn machine coordinates of 1st reference point of each
axis;
REF2_COORDn machine coordinates of 2nd reference point of each axis;
REF3_COORDn machine coordinates of 3rd reference point of each axis;
REF4_COORDn machine coordinates of 4th reference point of each axis.
[Data unit]
Set unit IS-B IS-C
Metric input 0.001 mm 0.0001 mm
Inch input 0.0001 inch 0.00001 inch
[Data range] -99999999~99999999
406
Volume Ⅲ Connection
3.2.6 Threading function
1 7 5 THDA
THDA 1: Exponential ACC&DEC for threading
0: Linear ACC&DEC for threading
0 1 9 THDCH
[Data meaning] thread run-out length in thread cutting.
[Data range] 0~225
Thread run-out width=THDCH×0.1×thread lead
0 2 6 THRDT
[Data meaning] short acceleration/deceleration time constant in thread run-out.
[Data unit] ms
[Data range] 0~4000
0 2 8 THDFL
[Data meaning] X, Z initial speed in thread cutting.
[Data unit]
Set unit Data unit
Metric machine mm/min
Inch machine 0.1inch/min
[Data range] 6~8000
0 7 0 ENCODER_CNT
[Data meaning] spindle encoder lines.