Inch input 0.0001 inch 0.00001 inch
Data range
IS-B IS-C
Metric input -9999999999 -999999999999
Inch input -9999999999 -999999999999
1 2 0 REF1_COORDn
1 2 1 REF2_COORDn
1 2 2 REF3_COORDn
1 2 3 REF4_COORDn
Data type Word axis
Data meaningREF1_COORDn machine coordinates of 1st reference point of each
axis;
REF2_COORDn machine coordinates of 2nd reference point of each axis;
REF3_COORDn machine coordinates of 3rd reference point of each axis;
REF4_COORDn machine coordinates of 4th reference point of each axis.
Data unit
Set unit IS-B IS-C
Metric input 0.001 mm 0.0001 mm
Inch input 0.0001 inch 0.00001 inch
Data range -9999999999999999
406
Volume Connection
3.2.6 Threading function
1 7 5 THDA
THDA 1: Exponential ACC&DEC for threading
0: Linear ACC&DEC for threading
0 1 9 THDCH
Data meaning thread run-out length in thread cutting.
Data range 0225
Thread run-out width=THDCH×0.1×thread lead
0 2 6 THRDT
Data meaning short acceleration/deceleration time constant in thread run-out.
Data unit ms
Data range 04000
0 2 8 THDFL
Data meaning X, Z initial speed in thread cutting.
Data unit
Set unit Data unit
Metric machine mm/min
Inch machine 0.1inch/min
Data range 68000
0 7 0 ENCODER_CNT
Data meaning spindle encoder lines.