EasyManua.ls Logo

TOMATECH TAC-100XT - Page 342

TOMATECH TAC-100XT
415 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TOMATECH AUTOMATION
0: For Z axis, press to execute the machine zero return.
Bit0 1: For X axis, press to execute the machine zero return;
0: For X axis, press to execute the machine zero return.
1 8 8 *** RRTn *** *** ***
[Data type] Bit axis
RRTn 1: when Y, 4th, 5th are rotary axis, the zero return use D mode;
0: when Y, 4th, 5th are rotary axis, the zero return use A, B,C mode( need to power-on
again).
0 3 3 ZRNFLn
[Data type] Word axis
[Data meaning] Lowest speed rate of X,Z machine zero return.
[Data unit]
Set unit Data unit
Metric machine mm/min
Inch machine 0.1inch/min
[Data range]
IS-B IS-C
Metric machine 6~4000 6~4000
Inch machine 3~1500 3~1500
0 4 7 PRSn
[Data type] Word axis
[Data meaning] Setting value of absolute coordinate after machine zero return is
performed
Chapter 3 Parameters
405
Volume Ⅲ Connection
[Data unit]
Setting unit IS-B IS-C
Metric input 0.001 mm 0.0001 mm
Inch input 0.0001 inch 0.00001 inch
[Data range] -99999999~99999999
1 1 3 REF_SPDn
[Data meaning] high-speed of each axis machine zero return.
[Data unit]
Set unit Data unit
Metric machine mm/min
Inch machine 0.1inch/min
[Data range] 10~99999999
1 1 4 REF_OFFSETn
[Data type] Word axis
[Data meaning] Offset value of each axis machine zero point
[Data unit]
Set unit IS-B IS-C
Metric input 0.001 mm 0.0001 mm

Table of Contents