EasyManua.ls Logo

TOMATECH TAC-100XT - PLC Parameters(Standard PLC Definition

TOMATECH TAC-100XT
415 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TOMATECH AUTOMATION
0 X axis
1 Z axis
2 Y axis
3 4th axis
4 5th axis
2 3 6 POLARTOSAXIS
[Data meaning] Rotary axis setting of the polar coordinate interpolation
[Data range] 2~4
Setting value Meaning
2 Y axis
3 4th axis
4 5th axis
2 3 7 ACCEPTANGLEERR
[Data meaning] Maximum fluctuating value when the angle is 0°or 180°for C tool offset
C
[Data range]
IS-B IS-C
0~1000 0~10000
2 4 0 HWRPDFRATE
[Data meaning] Rapid traverse override of MPG trial cut function
[Data range] 0~100
Chapter 3 Parameters
393
Volume Ⅲ Connection
2 4 1 HWPULSEINC
[Data meaning] Movement amount per pulse during trial cut function
[Data range] 0~100
3.1.3 PLC parameters(standard PLC definition)
3.1.3.1 K parameters
K 1 0 LMIT LMIS *** JSPD OVRI *** RSJG RRW
Bit7 1: overtravel of each axis is enabled;
0: overtravel of each axis is disabled.
Bit6 1: alarm for overtravel signal LOW of each axis;
0: alarm for overtravel signal LOW of each axis
Bit4 1: spindle JOG is enabled in any modes;
0: spindle JOG is enabled in Manual, MPG, Zero Return mode.
Bit3 1: feedrate override is fixed to 100%;
0: feedrate override can be adjusted.
Bit1 1: spindle lubricating, cooling output remain in reset;
0: spindle lubricating, cooling output are disabled in reset.
Bit0 1: the cursor returning to the beginning of the program is enabled in any working
mode in
reset;
0: the cursor returning to the beginning of the program is enabled in Edit working mode.

Table of Contents