TOMATECH AUTOMATION
0 X axis
1 Z axis
2 Y axis
3 4th axis
4 5th axis
2 3 6 POLARTOSAXIS
Data meaning Rotary axis setting of the polar coordinate interpolation
Data range 2~4
Setting value Meaning
2 Y axis
3 4th axis
4 5th axis
2 3 7 ACCEPTANGLEERR
Data meaning Maximum fluctuating value when the angle is or 180°for C tool offset
C
Data range
IS-B IS-C
01000 010000
2 4 0 HWRPDFRATE
Data meaning Rapid traverse override of MPG trial cut function
Data range 0100
Chapter 3 Parameters
393
Volume Connection
2 4 1 HWPULSEINC
Data meaning Movement amount per pulse during trial cut function
Data range 0100
3.1.3 PLC parametersstandard PLC definition
3.1.3.1 K parameters
K 1 0 LMIT LMIS *** JSPD OVRI *** RSJG RRW
Bit7 1: overtravel of each axis is enabled;
0: overtravel of each axis is disabled.
Bit6 1: alarm for overtravel signal LOW of each axis;
0: alarm for overtravel signal LOW of each axis
Bit4 1: spindle JOG is enabled in any modes;
0: spindle JOG is enabled in Manual, MPG, Zero Return mode.
Bit3 1: feedrate override is fixed to 100%;
0: feedrate override can be adjusted.
Bit1 1: spindle lubricating, cooling output remain in reset;
0: spindle lubricating, cooling output are disabled in reset.
Bit0 1: the cursor returning to the beginning of the program is enabled in any working
mode in
reset;
0: the cursor returning to the beginning of the program is enabled in Edit working mode.