TOMATECH AUTOMATION
[Data range] 0~6000
2 1 6 ROT_REVn
[Data type] Word axis
[Data meaning] movement pre rev when the additional axis is rotary
[Data unit]
Setting unit IS-B IS-C
Rotary axis 0.001 deg 0.0001 deg
[Data range] 1000~99999999
2 1 9 PLCDIDOn
[Data type] Word axis
[Data meaning] Select DI/DO according to PLC controlled axes (0 means PLC axis
control is
not applied)
[Data unit]
[Data range] 0~4
2 2 4 AXISNUM
[Data meaning] Axis number displayed on the screen
[Data unit]
[Data range] 2~5
2 2 5 NAME_n
[Data type] Word axis
[Data meaning] Axis name definition of each axis
[Data range] 65, 66, 67, 88, 89, 90
Axis name Setting value Axis name Setting value Axis name Setting value
X 88 A 65 C 67
392
Volume Ⅲ Connection
Z 90 B 66 Y 89
2 3 0 ATTRIB_n
[Data meaning] ATTRIB_n is the additional attribution setting
[Data range] 0~7
Setting value Meaning
0 It is neither the three basic axes and an axis parallel to them
1 X axis of the three basic axes
2 Y axis of the three basic axes
3 Z axis of the three basic axes
5 An axis parallel to X
6 An axis parallel to Y
7 An axis parallel to Z
2 3 5 POLARLINEAXIS
[Data meaning] Linear axis setting of the polar coordinate interpolation
[Data range] 0~4
Setting value Meaning