TOMATECH AUTOMATION
Data range 06000
2 1 6 ROT_REVn
Data type Word axis
Data meaning movement pre rev when the additional axis is rotary
Data unit
Setting unit IS-B IS-C
Rotary axis 0.001 deg 0.0001 deg
Data range 100099999999
2 1 9 PLCDIDOn
Data type Word axis
Data meaning Select DI/DO according to PLC controlled axes (0 means PLC axis
control is
not applied)
Data unit
Data range 04
2 2 4 AXISNUM
Data meaning Axis number displayed on the screen
Data unit
Data range 25
2 2 5 NAME_n
Data type Word axis
Data meaning Axis name definition of each axis
Data range 65, 66, 67, 88, 89, 90
Axis name Setting value Axis name Setting value Axis name Setting value
X 88 A 65 C 67
392
Volume Connection
Z 90 B 66 Y 89
2 3 0 ATTRIB_n
Data meaning ATTRIB_n is the additional attribution setting
Data range 0~7
Setting value Meaning
0 It is neither the three basic axes and an axis parallel to them
1 X axis of the three basic axes
2 Y axis of the three basic axes
3 Z axis of the three basic axes
5 An axis parallel to X
6 An axis parallel to Y
7 An axis parallel to Z
2 3 5 POLARLINEAXIS
Data meaning Linear axis setting of the polar coordinate interpolation
Data range 0~4
Setting value Meaning