TOMATECH AUTOMATION
password
Resume
operation
Part programs More than 4th grade(including the 4th grade)
password
11.4 Notes
The user should pay more attention to the followings during executing the data
backup/resume
operation:
1) Need more than the 2nd grade password(including the 2nd grade) to resume more than
(including be equal to) 9000 part programs;
2) Backup/resume operation must be in MDI mode;
3) When the user executes the data backup operation, the system automatically replaces
all
files in “U:\TAC-100XT_backup\user”, the user should save them as when they cannot be
replaced;
4) Stop part programs running before data backup/resume;
5) They must not stop unless the data backup/resume operation is completed;
6) The system is turned on again after the data resume is done.
290
Ⅱ Operation
CHAPTER 12 COMMUNICATION
12.1TAC-1002T Communication Software TOMATECHComm
TOMATECHComm is an allocated project administrator. It can execute the
upload/download between
PC and CNC, conveniently transmit batch with easy operation, high communication
efficiency and
reliability.
The followings introduce communication transmission and setting betweenTAC-1002T
and
TOMATECHComm. Refer to TOMATECHComm explanations about TOMATECHComm
communication software functions.
12.1.1 TOMATECHComm’s system (PC) requirements
Hardware: general PC with RS232 serial port, serial communication cable (3-wire)
Operation system: Microsoft Windows 98/2000/XP/2003
12.1.2 Software interface
Interface after TOMATECHComm’s initial run:
Fig. 12-1 file download(PC→CNC)interface