TOMATECH AUTOMATION
Bit4 1: Do not detect software stroke limit;
0: Detect software stroke limit.
Bit3 1: Emergency stop inactive;
0: Emergency stop active;
Bit1 1: The software limit is valid after system is energized and before machine zero return
is
performed;
0: The software limit is invalid after system is energized and before machine zero return is
performed;
0 4 5 LT1n1
0 4 6 LT1n2
[Data type] Word axis
[Data meaning] LT1n1: Maximum stroke on positive direction; LT1n2: Maximum stroke
on
negative direction
[Data Unit]
Setting unit IS-B IS-C
Metric machine 0.001 mm 0.0001 mm
Inch 0.0001 inch 0.00001 inch
[Data range] -99999999~99999999
Note: When bit 2 of parameter No. 001 set diameter programming, X axis is set by diameter system;
when bit 2 set
radius programming, X axis is set by radius system.
PLC parameter
D T 0 2 PEALMTIM
[Data meaning] Under-pressure alarm detection time
[Data unit] ms
[Data range] 0~2147483647
Chapter 3 Parameters
403
Volume Ⅲ Connection
D T 2 1 PSANGNT
[Data meaning] Chuck operation delay time after spindle stop;
[Data unit] ms
[Data range] 0~2147483647
3.2.5 Machine zero return
0 0 4 *** DECI ***
Bit5 1: Deceleration begins as DEC signal is connected to +24V in machine zero return
0: Deceleration begins as DEC signal is disconnected to +24V in machine zero return
0 0 5 PPD
Bit1 1: Relative and absolute coordinate set together for absolute setting and reference
return by
G50
0: Only absolute coordinate set for absolute setting and reference point by G50