TOMATECH AUTOMATION
c) Move the cursor to the parameter number to be set(the method is referred to Section
10.4.1 Step c);
d) Press to enter the bit alteration mode, at the moment, some bit of the parameter
is backlighted. Press or to move the cursor to the bit to be altered, then key in 0 or
1;
e) After all parameters setting is finished, the PARM SWT needs to be set to OFF for
security.
Note: After the system enters some bit of the parameter, is pressed to escape from the
alteration mode, and the cursor stops the parameter number .
Example:
Set the Bit3 of the bit parameter No.001 to 1, and the other bits remains unchanged.
Move the cursor to No.001 according to the above steps, press to skip to some bit of the
parameter, and move the cursor to Bit3. The display is shown below:
278
Ⅱ Operation
Input 1, and the parameter alteration is done.
10.4.2 Data parameter, pitch compensation
1) Turn on the parameter switch;
2) Enter the MDI mode;
3) Move the cursor to the No. of the parameter to be set;
4) Key in the new parameter value;
5) Press key, the value is entered and displayed;
6) After all parameters setting is finished, the PARM SWT needs to be set to OFF for
security.
Explanation: The screw-pitch parameter can only be altered under the 2 level password authority.
Example 1: set the data parameter No.027 to 7600.
Chapter 10 Data Setting, Backup and Restore
279
Ⅱ Operation
Move the cursor to No.027 by the steps above, key in 7600 by sequence as follows:
Press to finish the alteration. The display is shown below:
Example 2: set X value of the screw-pitch parameter No.000 to 12.
Move the cursor to screw-pitch parameter No.000 by the steps above, key in 12 in order
as
follows:
280
Ⅱ Operation
Press key to finish the alteration. The display page is shown below:
10.4.3 Often used parameters
Press to enter parameter interface, and press to enter the often used parameter