K 1 1 CHOT CHET TCPS CTCP TSGN CHTB CHTA
Bit7 1: checks the tool post worktable overheating;
0: does not check the tool post worktable overheating.
Bit5 1: checks the tool signal when the tool change is completed;
0: does not check the tool signal when the tool change is completed.
Bit4 1: tool post locking signal HIGH(be connected with +24V) is enabled;
0: tool post locking signal LOW(not be connected with +24V) is enabled
Bit3 1: checks the tool post locking signal;
0: does not check the tool post locking signal.
Bit2 1: tool signal LOW(not be connected with +24V) is enabled;
0: tool signal HIGH(be connected with +24V)is enabled.
Bit1 Bit0 : tool change mode selects Bit1 tool change mode selects Bit 0
K 1 2 RCKC CCHU NYQP SLSP SLQP
Bit4 1: External chuck control is enabled during program running;
0: External chuck control is disabled during program running
Bit3 1: the system checks the chuck in-position signal;
0: the system does not check the chuck in-position signal.
CHTB CHTA Tool post type
0 0 Standard tool change mode B
0 1 Standard tool change mode A
1 0 Yantai AK31 series(6, 8, 10, 12 tools)
1 1 Liuxin hydraulic tool post8, 10, 12 tools
394
Volume Connection
Bit2 1: in outer mode, NQPJ is the outer chuck released signal, and WQPJ is the outer
chuck
clamped signal;
0: in inner mode, NQPJ is the inner chuck clamped signal, and WQPJ is the inner chuck
released signal.
Bit1 1: the system does not check whether the chuck is clamped when the chuck function
is
enabled;
0: the system checks whether the chuck is clamped when the chuck function is enabled;
when the chuck is not clamped, the system cannot start the spindle and alarms.
Bit0 1: the chuck control function is enabled;
0: the chuck control function is disabled.
K 1 3 RTSC SPTW SLTW
Bit2 1: External tailstock control is enabled during program running;
0: External tailstock control is disabled during program running;
Bit1 1: the spindle rotation and the tailstock forward/backward does not interlock, the
tailstock
executes the forward no matter what the spindle is in any states; the spindle rotates no
matter what the tailstock is in any states;