0: the spindle rotation and the tailstock forward/backward interlock, the tailstock cannot
execute the forward when the spindle rotates; the spindle cannot be started when the
tailstock does not execute the forward.
Bit0 1: the tailstock control function is enabled;
0: the tailstock control function is disabled.
K 1 4 HPST SGSP SPB4 PB4 SPB3 PB3
Bit7 1: the hydraulic control function is enabled;
0: the hydraulic control function is disabled.
Bit4 1: Spindle is enabled when the protection door is open
0: Spindle is disabled when the protection door is open;
Bit3 1: when SAGT is connected with +24V, the safety door is disabled;
0: when SAGT is not connected with +24V, the safety door is disabled.
Bit2 1: the safety door check function is enabled;
0: the safety door check function is disabled.
Bit1 1: when PRES is not connected with +24V,the system alarms for pressure LOW;
0: when PRES is connected with +24V,the system alarms for pressure LOW.
Bit0 1: the pressure LOW check function is enabled;
0: the pressure LOW check function is disabled.
K 1 5 RCS RSCS SPOR SHT AGIM AGIN AGER
Bit7 1: Cs function is enabled;
0: Cs function is disabled.
Bit6 1: the spindle contour control is disabled in emergency stop, reset;
0: the spindle contour control is enabled in emergency stop, reset.
Bit5 1: the spindle eight-point orientation function is enabled;
0: the spindle eight-point orientation function is disabled.
Bit3 1: the spindle gear power-down memory;
0: the spindle gear power-down does not execute the memory.
Chapter 3 Parameters
395
Volume Ⅲ Connection
Bit2 1: the gear in-position signal M41I, M42I which are not connected with +24V is
enabled;
0: the gear in-position signal M41I, M42I which are connected with +24V is enabled.
Bit1 1: when the spindle automatic gear change is to Gear 1, 2, the system checks the
gear
change in-position signal M41I, M42I;
0: when the spindle automatic gear change is to Gear 1, 2, the system does not check the
gear change in-position signal M41I, M42I.
Bit0 1: the spindle automatic gear change function is enabled;
0: the spindle automatic gear change function is disabled
K 1 6 SINC SINC2 SPWM CLWM M32A ROVI SOVI
Bit7 1: When Step(MPG)mode×1000-gear is disabled,×1, ×10, ×100 gear is enabled;
0: When Step(MPG)mode×1000-gear is disabled,×1, ×10, ×100, x1000 gear is enabled.
Bit6 1: When the increment is 1u, gear “×1000” in STEP (MPG) mode is disabled;