TOMATECH AUTOMATION
0: When the increment is 1u, gear “×1000” in STEP (MPG) mode is enabled;
Bit5 1: When spindle stop command is in the same block with movement command, these
commands are executed at the same time;
0: When spindle stop command is in the same block with movement command,
movement
command comes first to spindle stop command;
Bit4 1: When cooling OFF command and movement command are in the same block, they
are
executed at the same time;
0: When cooling OFF command and movement command are in the same block,
movement
command comes first to the cooling OFF command;
Bit2 1: the lubricating outputs in power-on when the automatic lubricating is enabled;
0: the lubricating does not output in power-on when the automatic lubricating is enabled.
Bit1 1: the external feedrate override inverses;
0: the external feedrate override does not inverse.
Bit0 1: the external feedrate override switch is enabled
0: the external feedrate override switch is disabled.
K 1 7 MSEN SCLP SALM2 SALM SSTP SONC
Bit7 1: the multiple spindle control function is enabled;
0: the multiple spindle control function is disabled.
Bit6 1: the spindle clamped command clamps the 2nd spindle when the multiple spindle is
enabled;
0: the spindle clamped command clamps the 1st spindle when the multiple spindle is
enabled
Bit5 1: the system alarms when the 2nd spindle is LOW;
0: the system alarms when the 2nd spindle is HIGH.
Bit4 1: the system alarms when the spindle is LOW;
0: the system alarms when the spindle is HIGH.
Bit3 1: the analog voltage is disabled when the spindle stops;
0: the analog voltage is enabled when the spindle stops.
Bit2 1: Spindle is disabled when clamping;
0: Spindle motor torque decreases to 0 when spindle is clamping;
K 1 8 EXTM RSTM HOLD *** MDOK MD4 MD2 MD1
396
Volume Connection
Bit7 1: extended M function is valid;
0: extended M function is invalid
Bit6 1: extended M function remains output when emergency stop, reset;
0: extended M function output closes when emergency stop, reset.
Bit5 1: HOLD release control is valid;
0: HOLD release control is invalid.
Bit3 1: the operation mode is specified by MD4, MD2, MD1 state when the system is