TOMATECH AUTOMATION
turned on;
0: the operation mode is the state which is that of power-off when the system is turned on.
MD4 MD2 MD1 Operation mode in power-on
0 0 0 MDI mode
0 0 1 Auto mode
0 1 0 Program zero return
0 1 1 Edit mode
1 0 0 MPG mode
1 0 1 Manual mode
1 1 0 Machine zero return
3.1.3.2 DT parameter
Address Meaning
DT000 Time for original gear disabling during spindle automatic
gear changing (ms)
DT001 Delay time after the changed spindle gear is in position (ms)
DT002 Detection time for low pressure alarm (ms)
DT004 Permit time for tool changing (ms)
DT005 M command execution time (ms)
DT006 S command execution time (ms)
DT007 Delay time for tool post from CW to CCW output (ms)
DT008 Tool post lock signal detection time (ms)
DT009 Tool post CCW rotation lock time (ms)
DT010 Spindle braking delay output time (ms)
DT011 Spindle braking output time (ms)
DT012 Spindle JOG time (ms)
DT013 Time for manual lubricating ON (0: time is not limited) (ms)
DT014 Chuck clamping command execution time (ms)
DT015 Chuck unclamping command execution time (ms)
DT016 Interval of automatic lubricating (ms) (can be modified
directly)
DT017 Time for automatic lubrication output (ms) (can be modified
directly)
DT018 Chuck pulse output width (ms) (can be modified directly)
DT020 Spindle clamping/unclamping time (ms)
DT021 Spindle stop, chuck enable delay time (ms)
DT023 Delay time before spindle motor torque decreases to 0 after
spindle starts clamping
Chapter 3 Parameters
397
Volume Ⅲ Connection
3.1.3.3 DC parameters
Address Meaning
DC000 Spindle zero speed output range (r/min)