TOMATECH AUTOMATION
system,01: IS-A,10: IS-B;11: IS-C.
Bit5 1: Cs function of additional axis is valid/invalid (power-on again);
0: Cs function of additional axis is valid/invalid (power-on again).
Bit1,Bit0: 00 sets the additional axis to be the linear, 01 sets the additional axis to be the
rotary(A
type),11 sets the additional axis to be the rotary (B type),10 sets the additional axis to
be invalid.
Note: This parameter is invalid to axes X and Z.
1 8 8 *** RRT *** *** *** RRL RAB ROA
[Data type]: Bit axis
Bit6 1: When the additional axis is rotary, the zero return uses D mode;
0: When the additional axis is rotary, the zero return uses A, B, C (power-on again).
Bit2 1: When the additional axis is rotary, cycle function of the relative coordinate is valid;
0: When the additional axis is rotary, cycle function of the relative coordinate is invalid
(power-on again).
Bit1 1: When the additional axis is rotary, its rotation direction is based on the sign
direction;
0: When the additional axis is rotary, its rotation direction is contiguous.
Bit0 1: When the additional axis is rotary, cycle function of the absolute coordinate is valid;
0: When the additional axis is rotary, cycle function of the absolute coordinate is invalid
(power-on again).
Note: This parameter is invalid to axes X and Z.
2 1 6 ROT_REVn
[Data type] Word axis
[Data meaning]Axis movement per rotation (when the auxiliary axes are rotary axes)
[Data unit]
Setting Unit IS-B IS-C
Rotary axis 0.001 deg 0.0001 deg
[Data range] 1000~99999999
2 2 4 AXISNUM
[Data meaning] The displayed axis number
[Data range] 2~5
414
Volume Ⅲ Connection
2 2 5 NAME_n
[Data type] Word axis
[Data meaning]axis name definitions
[Data range] 65, 66, 67, 88, 89, 90
Axis name Setting value Axis name Setting value Axis name Setting value
X 88 A 65 C 67
Z 90 B 66 Y 89
2 3 0 ATTRIB_n
[Data type] Word axis