=0: pressing cannot start the program run in MDI mode.
OVRI =1: feedrate override is fixed to 100%;
=0: feedrate override can be adjusted.
JSPD =1: the spindle JOG in any modes are valid;
=0: the spindle JOG in MANUAL, MPG, ZERO RETURN are valid.
LMIS =1: overtravel signal LOW/HIGH alarm of each axis;
=0: overtravel signal LOW/HIGH alarm of each axis.
LMIT =1: overtravel of each axis is valid;
=0: overtravel of each axis is invalid.
K 1 1 CHOT *** CHET TCPS CTCP TSGN CHTB CHTA
CHTA: tool change mode selection bit 0
CHTB: tool change mode selection bit 1(see table below)
TSGN =0: tool signal HIGH (be connected to +24V) is valid
=1: tool signal HIGH (be not connected to +24V) is valid
CTCP =0: do not check the tool post lock signal
=1: check the tool post lock signal
TCPS =0: tool post lock signal LOW(be not connected to +24V) is valid
=1: tool post lock signal LOW(be connected to +24V) is valid
CHET=0: do check the tool signal when the tool change ends
=1: check the tool signal when the tool change ends
CHTB CHTA Tool post type
0 0 Standard tool change mode B
0 1 Standard tool change mode A
1 0 Yantai AK31 series(6, 8,10, 12 tools)
1 1 Liuxin hydraulic tool post(8, 10, 12 tools)
442
Ⅲ Connection
CHOT=0: do not check the tool post overheat
=1: check the tool post overheat
SLQP =1: chuck control function is valid;
=0: chuck control function is invalid.
SLSP =1: when the chuck function is valid, the system does not check whether the chuck
is
clamped;
=0: when the chuck function is valid, the system checks whether the chuck is clamped;
when the chuck is not clamped and the spindle cannot be stated, the system alarms.
NYQP =1: in outer mode, NQPJ is outer chuck release signal, WQPJ is outer clamp
signal;
=0: in inner mode, NQPJ is outer chuck clamp signal, WQPJ is outer release signal.
CCHU =1: the system checks the chuck in-position signal, No.002 Bit7 is inner chuck
clamp/outer release signal NQPJ, BIT6 is outer clamp/inner release signal WQPJ,
the spindle gear shifting in-position signal M411, M421 is invalid.
=0: the system does not check the chuck in-position signal.