TOMATECH AUTOMATION
ZSSY2080 MPG
Chapter 2 Definition and Connection of Interface Signal
365
Ⅲ Connection
9 X6.3 EMP0 Increment ×1
22 X6.4 EMP1 Increment ×10
23 X6.5 EMP2 Increment ×100
11, 12, 13 GND
14,15 +5V
17,18 +24V
� Related parameters
State parameter
0 0 1 MPG
Bit3 =0: Step working mode.
=1: MPG working mode.
PLC status parameters
K 1 6 SINC SINC2
SINC =0: When the system increment is 0.1μ, gear ×1000 in MPG and STEP mode is
valid;
=1: When the system increment is 0.1μ, gear ×1000 in MPG and STEP mode is invalid;
SINC2 =0: When the system increment is 1μ, gear ×1000 in MPG and STEP mode is
valid;
=1: When the system increment is 1μ, gear ×1000 in MPG and STEP mode is invalid;
� Function description
① When SINC is set to 0.1, MPG/STEP mode ×1000-gear selection is disabled. When
x1000-gearis selected before modifying the parameter, the system automatically changes
into
×100-gear;
② When SINC is set to 1, MPG/STEP mode ×1000-gear selection is disabled. When
x1000-gearis
selected before modifying the parameter, the system automatically changes into
×100-gear;
③ When the external MPG, its axis selection does not lock, that is, the axis selection of
MPG is
disabled, the system changes to the non-axis selection state.
④ When the external MPG axis selection and gear selection input are enabled, the axis
selection
on the panel and the gear selection keys are disabled; when the external MPG axis
selection and
gear selection input are disabled, the axis selection on the panel and the gear selection
keys are
enabled and self-locked.
2.8.22 Tri-color Lamp
� Relevant signals and function definition (standard PLC program)