EasyManua.ls Logo

TOMATECH TAC-100XT - Page 266

TOMATECH TAC-100XT
415 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TOMATECH AUTOMATION
the motor brake is turned on.
.When the system delays 200msit closes the pregraduation electromagnetic output
signal,
and then the electromagnet is turned off.
.The system checks the current tool no. again and confirms whether the encoding signal
of the
Chapter 2 Definition and Connection of Interface Signal
329
Connection
current tool is consistent with the target tool no..
.The system confirms again whether the locked proximity switch signal is HIGH.
.When the above steps are correct, the system closes the tool post brake signal TZD,
and so
the tool change is completed.
.In the course of the tool change, when the system has found the motor overheat signal,
it
alarms and closes output of all signals.
b). Tool change flow
330
Connection
Chapter 2 Definition and Connection of Interface Signal
331
Connection
4. CHTB (K11.1)=1CHTA(K11.0)=1: Liuxin hydraulic tool post
4.1 . Corresponding table between position and signal
8-tool:
1 2 3 4 5 6 7 8
A ● ● ● ●
B ● ● ● ●
C ● ● ● ●
D ● ● ● ●
E ● ● ● ● ● ● ●
10-tool:
1 2 3 4 5 6 7 8 9 10
A ● ● ● ● ●
B ● ● ● ●
C ● ● ● ●
D ● ● ● ●
E ● ● ● ● ● ● ● ● ● ●
12-tool:
1 2 3 4 5 6 7 8 9 10 11 12
A ● ● ● ● ● ●
B ● ● ● ● ● ●

Table of Contents