TOMATECH AUTOMATION
deceleration signal and zero-point signal at the same time).
Bit 2 1: During machine zero return, the deceleration signal of the Y axis (DECY) and
one-rotation
signal (PCY) are connected in parallel (use a proximity switch as a deceleration signal and
zero-point signal at the same time).
0: During machine zero return, the deceleration signal of the Y axis (DECY) and
one-rotation
signal (PCY) are connected separately (use a proximity switch as a deceleration signal
and zero-point signal at the same time).
Bit 1 1: During machine zero return, the deceleration signal of the Z axis (DECZ) and
one-rotation
signal (PCZ) are connected in parallel (use a proximity switch as a deceleration signal and
zero-point signal at the same time).
0: During machine zero return, the deceleration signal of the Z axis (DECZ) and
one-rotation signal (PCZ) are connected separately (use a proximity switch as a
deceleration signal and zero-point signal at the same time).
Bit 0 1: During machine zero return, the deceleration signal of the X axis (DECX) and
one-rotation
signal (PCX) are connected in parallel (use a proximity switch as a deceleration signal and
zero-point signal at the same time).
0: During machine zero return, the deceleration signal of the X axis (DECX) and
one-rotation
signal (PCX) are connected separately (use a proximity switch as a deceleration signal
and zero-point signal at the same time).
0 1 1 NORF ZNLK
Bit3 1: Manual machine zero return is invalid;
0: Manual machine zero return is valid;
Bit 2: 1: The direction key is self-locked during machine zero return; press the direction
key once till
the machine zero return is finished;
0: The direction key is not self-locked during machine zero return; press down the
direction key;
0 1 2 APRS ISOT
Bit 7 1: CNC sets the absolute coordinate system automatically after reference point
return;
0: CNC does not set absolute coordinate system automatically after reference point
return;
Bit 0 1: Manual rapid traverse is valid after system power-on and before machine zero
return;
0: Manual rapid traverse is invalid after system power-on and before machine zero return;
0 1 4 ZRS5 ZRS4 ZRSY ZRSZ ZRSX
Bit4, Bit3, Bit2, Bit1, Bit0
1: Machine zero point is set on the 5th, 4th, Y, Z, X axes; deceleration signal and zero point
signal are