TOMATECH AUTOMATION
SCLP CN62.7 Y0.6 Spindle clamped
SPZD CN62.8 Y0.7 Spindle brake
SVF CN62.37 Y3.0 Spindle servo OFF
Output
signal
SFR CN15.22 Y5.2 Spindle rotation(CW)
Its function is
consistent with
that of M03
Chapter 2 Definition and Connection of Interface Signal
339
Connection
SRV CN15.23 Y5.3 Spindle rotation(CCW)
Its function is
consistent with
that of M04
M03 Spindle rotation(CCW)
M04 Spindle rotation(CW)
M05 Spindle stop
M20 Spindle clamped
Command
format
M21 Spindle released
They are valid in
analog spindle
Control parameter
Bit parameter
K 1 0 RSJG
RSJG =1: CNC not turn off M03, M04, M08, M32 output signals when pressing key;
=0: CNC turns off M03, M04, M08, M32 output signals when pressing key.
K 1 7 SCLP SALM SSTP SONC
SCLP =1: The spindle clamped command executes clamping the 2nd spindle when the
multi-spindle is valid.
=0: The spindle clamped command executes clamping the 1st spindle when the
multi-spindle is valid.
SALM =1: The system alarms when the spindle abnormal detection input signal is LOW (it
is
turned off with 0V);
=0: The system alarms when the spindle abnormal detection input signal is HIGH (it is
turned on with 0V) .
SSTP =1: The analog voltage is closed when the spindle stops;
=0: The analog voltage is not closed when the spindle stops.
SONC = 1: Spindle is disabled when clamping
= 0: Spindle motor torque decreases to 0 when spindle is clamping;