Data unit mV
Data range 010000
0 6 8 SJOGREV
Data meaning spindle rotary axis speed in Manual (MPG) mode.
Data unit r/min
Data range 03000
0 6 9 PEALMTIM
Data meaning pressure low alarm time width.
Data unit ms
Data range 060000
0 7 0 ENCODER_CNT
Data meaning spindle encoder lines.
Data unit line/r
408
Volume Connection
Data range 1005000
0 7 1 RESET_TIME
Data meaning reset signal output time.
Data unit ms
Data range 164080
0 7 2 SAR_DELEY
Data meaning spindle speed arrival signal delay check time.
Data unit ms
Data range 04080
0 7 3 SPMOTORMAX
Data meaning max. clamp speed of spindle motor speed.
Data unit r/min
Data range 04095
Setting value=max. clamp speed of spindle motor/its max. speed×4095.
0 7 4 SPMOTORMIN
Data meaning min. clamp speed of spindle motor speed.
Data unit r/min
Data range 04095
Setting value=min. clamp speed of spindle motor/its min. speed×4095.
0 7 5 SPSPEEDLIMIT
Data meaning max. spindle speed 0: not limit speed.
Data unit r/min
Data range 06000
1 0 9 SPL_REV_SPD
Data meaning rotary speed in spindle jog.
Chapter 3 Parameters
409
Volume Connection

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TOMATECH TAC-100XT and is the answer not in the manual?

TOMATECH TAC-100XT Specifications

General IconGeneral
BrandTOMATECH
ModelTAC-100XT
CategoryControl Systems
LanguageEnglish