[Data unit] mV
[Data range] 0~10000
0 6 8 SJOGREV
[Data meaning] spindle rotary axis speed in Manual (MPG) mode.
[Data unit] r/min
[Data range] 0~3000
0 6 9 PEALMTIM
[Data meaning] pressure low alarm time width.
[Data unit] ms
[Data range] 0~60000
0 7 0 ENCODER_CNT
[Data meaning] spindle encoder lines.
[Data unit] line/r
408
Volume Ⅲ Connection
[Data range] 100~5000
0 7 1 RESET_TIME
[Data meaning] reset signal output time.
[Data unit] ms
[Data range] 16~4080
0 7 2 SAR_DELEY
[Data meaning] spindle speed arrival signal delay check time.
[Data unit] ms
[Data range] 0~4080
0 7 3 SPMOTORMAX
[Data meaning] max. clamp speed of spindle motor speed.
[Data unit] r/min
[Data range] 0~4095
Setting value=(max. clamp speed of spindle motor/its max. speed)×4095.
0 7 4 SPMOTORMIN
[Data meaning] min. clamp speed of spindle motor speed.
[Data unit] r/min
[Data range] 0~4095
Setting value=(min. clamp speed of spindle motor/its min. speed)×4095.
0 7 5 SPSPEEDLIMIT
[Data meaning] max. spindle speed [0: not limit speed].
[Data unit] r/min
[Data range] 0~6000
1 0 9 SPL_REV_SPD
[Data meaning] rotary speed in spindle jog.
Chapter 3 Parameters