EasyManua.ls Logo

YASKAWA GA700 - Page 273

YASKAWA GA700
1053 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Standards Compliance
4
4.3 UL Standards
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual 273
WARNING! Electrical Shock Hazard. Do not immediately energize the drive or operate peripheral devices after the drive blows
a fuse or trips an RCM/RCD. Wait for the time specified on the warning label at a minimum and make sure that all indicators are
OFF. Then check the wiring and peripheral device ratings to find the cause of the problem. Contact Yaskawa before energizing
the drive or peripheral devices if the cause is not known. Failure to obey can cause death or serious injury and damage to the
drive.
200 V class
Use the fuses specified in this document to prepare the drive for use on a circuit that supplies not more than
100,000 RMS symmetrical amperes and 240 Vac when there is a short circuit in the power supply.
400 V class
Use the fuses specified in this document to prepare the drive for use on a circuit that supplies not more than
100,000 RMS symmetrical amperes and 480 Vac when there is a short circuit in the power supply.
The built-in short circuit protection of the drive does not provide branch circuit protection. The user must provide
branch circuit protection as specified by the National Electric Code (NEC), the Canadian Electric Code, Part I
(CEC), and local codes.
Table 4.14 Factory-Recommended Branch Circuit Protection: 200 V Class (ND)
Drive Model
Maximum Applicable Motor
Output
kW (HP)
Input Current Rating
A
Semiconductor Protection
Fuse Rated Current
Manufacturer: EATON/
Bussmann
2004 0.75 (0.75) 4.8 FWH-45B
2006 1.1 (1.5) 6.7 FWH-45B
2010 2.2 (3) 12.7 FWH-45B
2012 3 (4) 17 FWH-100B
2018 3.7 (5) 20.7 FWH-100B
2021 5.5 (7.5) 30 FWH-100B
2030 7.5 (10) 40.3 FWH-125B
2042 11 (15) 52 FWH-150B
2056 15 (20) 78.4 FWH-200B
2070 18.5 (25) 96 FWH-225A
2082 22 (30) 114
FWH-225A
FWH-250A
*1
2110 30 (40) 111
FWH-225A
FWH-250A
*1
2138 37 (50) 136
FWH-275A
FWH-300A
*1
2169 45 (60) 164
FWH-275A
FWH-350A
*1
2211 55 (75) 200
FWH-325A
FWH-450A
*1
2257 75 (100) 271 FWH-600A
2313 90 (125) 324 FWH-800A
2360 110 (150) 394 FWH-1000A
2415 - - -
*1 Yaskawa recommends a fuse with a large rated current for applications with repeated loads.
Table 4.15 Factory-Recommended Branch Circuit Protection: 200 V Class (HD)
Drive Model
Maximum Applicable Motor
Output
kW (HP)
Input Current Rating
A
Semiconductor Protection
Fuse Rated Current
Manufacturer: EATON/
Bussmann
2004 0.55 (0.5) 3.6 FWH-45B
2006 0.75 (1) 4.8 FWH-45B
2010 1.5 (2) 8.9 FWH-45B

Table of Contents

Other manuals for YASKAWA GA700