Parameter List
10
10.21 Defaults by Drive Model and Duty Rating ND/HD
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual 625
No.
*1
Name Unit Default
-
Drive
Model
- 2012 2018 2021 2030
C6-01
Normal /
Heavy
Duty
Selection
-
HD (ND) HD1 ND1 HD1 ND1 HD (ND)
0 1 0 1 0 1 0 1
o2-04
Drive
Model
(KVA)
Selection
Hex. 66 67 68 6A
E2-11
(E4-11)
Motor
Rated
Power
(kW)
kW 2.2 3.0 3.0 3.7 3.7 5.5 5.5 7.5
b3-04
V/f Gain
during
Speed
Search
% 100 100 100 100 100 100 100 100
b3-06
Speed
Estimation
Current
Level 1
- 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
b3-08
Speed
Estimation
ACR P
Gain
- 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
b3-26
Direction
Determina
tion Level
- 1000 1000 1000 1000 1000 1000 1000 1000
b8-03
Energy
Saving
Filter Time
s 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50
b8-04
Energy
Saving
Coefficient
Value
- 156.8 136.4 136.4 122.9 122.9 94.75 94.75 72.69
C5-17
(C5-37)
Motor
Inertia
kgm
2
0.0088 0.0158 0.0158 0.0158 0.0158 0.0255 0.026 0.037
C6-02
Carrier
Frequency
Selection
- 1 7 1 7 1 7 1 7
E2-01
(E4-01)
Motor
Rated
Current
(FLA)
A 8.5 11.4 11.4 14 14 19.6 19.6 26.6
E2-02
(E4-02)
Motor
Rated Slip
Hz 2.9 2.7 2.7 2.73 2.73 1.5 1.5 1.3
E2-03
(E4-03)
Motor No-
Load
Current
A 3 3.7 3.7 4.5 4.5 5.1 5.1 8
E2-05
(E4-05)
Motor
Line-to-
Line
Resistance
Ω 1.601 1.034 1.034 0.771 0.771 0.399 0.399 0.288
E2-06
(E4-06)
Motor
Leakage
Inductance
% 18.4 19 19 19.6 19.6 18.2 18.2 15.5
E2-10
(E4-10)
Motor Iron
Loss
W 77 91 91 112 112 172 172 262
E5-01
PM Motor
Code
Selection
- 1206 1206 FFFF FFFF 1208 1208 120A 120A