10.22 Parameters Changed by PM Motor Code Selection
654 YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
No. Name Unit Motor Code (setting value of E5-01)
n5-02
Motor Acceleration
Time
s 0.085 0.080 0.122 0.108 0.161 0.160 0.175
n8-49
d-Axis Cur
forHighEfficiency
Cont
% -10.7 -13.2 -15.7 -11.5 -7.0 -11.8 -10.2
*1 Default settings vary depending on the setting of o2-04 (Drive Model Selection).
Table 10.13 SSR1 Series Motor Code Setting for Specification of 400 V at 1450 min
-1
(r/min)
No. Name Unit Motor Code (setting value of E5-01)
E5-01
PM Motor Code
Selection
- 1332 1333 1335 1336 1338 133A 133B 133D
Voltage Class V 400 400 400 400 400 400 400 400
Capacity kW 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11
Motor Rotation
Speed
min
-1
1450 1450 1450 1450 1450 1450 1450 1450
E5-02
PM Motor Rated
Power (kW)
kW 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11.0
E5-03
PM Motor Rated
Current (FLA)
A 0.94 1.56 2.81 4.27 6.98 10.21 13.85 19.5
E5-04
PM Motor Pole
Count
- 6 6 6 6 6 6 6 6
E5-05
PM Motor
Resistance (ohms/
phase)
Ω 12.760 7.421 4.825 2.656 1.353 0.999 0.713 0.393
E5-06
PM d-axis
Inductance (mH/
phase)
mH 128.60 85.11 58.87 46.42 31.73 26.20 27.06 15.51
E5-07
PM q-axis
Inductance (mH/
phase)
mH 166.96 113.19 80.59 60.32 40.45 30.94 33.45 19.63
E5-09
PM Back-EMF
Vpeak (mV/(rad/
s))
mVs/rad 528.6 544.2 568.5 572.8 562.9 587.6 670.1 612.7
E5-24
PM Motor
Induced Voltage
Constant 2 (Ke)
mV/(r/
min)
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
E1-04
Maximum Output
Frequency
Hz 72.5 72.5 72.5 72.5 72.5 72.5 72.5 72.5
E1-05
Maximum Output
Voltage
V 380.0 380.0 380.0 380.0 380.0 380.0 380.0 380.0
E1-06 Base Frequency Hz 72.5 72.5 72.5 72.5 72.5 72.5 72.5 72.5
E1-09
Minimum Output
Frequency
Hz 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6
C5-17 Motor Inertia kgm
2
0.0017 0.0023 0.0043 0.0083 0.0136 0.017 0.027 0.046
L3-24
*1
Motor Accel Time
for Inertia Cal
s 0.098 0.071 0.066 0.087 0.085 0.072 0.084 0.096
n5-02
Motor
Acceleration Time
s 0.098 0.071 0.066 0.087 0.085 0.072 0.084 0.096
n8-49
d-Axis Cur
forHighEfficiency
Cont
% -6.6 -9.2 -13.5 -12.1 -13.7 -10.1 -12.2 -15.5
*1 Default settings vary depending on the setting of o2-04 (Drive Model Selection).