Parameter List
10
10.22 Parameters Changed by PM Motor Code Selection
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual 655
Table 10.14 SSR1 Series Motor Code Setting for Specification of 400 V at 1450 min
-1
(r/min)
No. Name Unit Motor Code (setting value of E5-01)
E5-01
PM Motor Code
Selection
- 133E 133F 1340 1342 1343 1344 1345
Voltage Class V 400 400 400 400 400 400 400
Capacity kW 15 18 22 30 37 45 55
Motor Rotation
Speed
min
-1
1450 1450 1450 1450 1450 1450 1450
E5-02
PM Motor Rated
Power (kW)
kW 15 18.50 22.00 30.00 37.00 45.00 55.00
E5-03
PM Motor Rated
Current (FLA)
A 27.4 32.9 37.6 52.5 63.2 76.4 96.1
E5-04
PM Motor Pole
Count
- 6 6 6 6 6 6 6
E5-05
PM Motor
Resistance (ohms/
phase)
Ω 0.295 0.223 0.164 0.137 0.093 0.059 0.048
E5-06
PM d-axis
Inductance (mH/
phase)
mH 12.65 9.87 7.90 7.01 5.93 4.17 3.11
E5-07
PM q-axis
Inductance (mH/
phase)
mH 15.87 12.40 10.38 8.68 6.79 5.22 4.55
E5-09
PM Back-EMF
Vpeak (mV/(rad/s))
mVs/rad 624.6 610.4 655.4 708.4 739.2 703.0 747.1
E5-24
PM Motor Induced
Voltage Constant 2
(Ke)
mV/(r/
min)
0.0 0.0 0.0 0.0 0.0 0.0 0.0
E1-04
Maximum Output
Frequency
Hz 72.5 72.5 72.5 72.5 72.5 72.5 72.5
E1-05
Maximum Output
Voltage
V 380.0 380.0 380.0 380.0 380.0 380.0 380.0
E1-06 Base Frequency Hz 72.5 72.5 72.5 72.5 72.5 72.5 72.5
E1-09
Minimum Output
Frequency
Hz 3.6 3.6 3.6 3.6 3.6 3.6 3.6
C5-17 Motor Inertia kgm
2
0.055 0.064 0.116 0.140 0.259 0.312 0.42
L3-24
*1
Motor Accel Time
for Inertia Cal
s 0.085 0.080 0.122 0.108 0.161 0.160 0.175
n5-02
Motor Acceleration
Time
s 0.085 0.080 0.122 0.108 0.161 0.160 0.175
n8-49
d-Axis Cur
forHighEfficiency
Cont
% -15.1 -16.0 -15.7 -11.5 -6.8 -11.5 -14.8
*1 Default settings vary depending on the setting of o2-04 (Drive Model Selection).
Table 10.15 SSR1 Series Motor Code Setting for Specification of 400 V at 1450 min
-1
(r/min)
No. Name Unit Motor Code (setting value of E5-01)
E5-01
PM Motor Code Selection - 1346 1347 1348 1349
Voltage Class V 400 400 400 400
Capacity kW 75 90 110 132
Motor Rotation Speed min
-1
1450 1450 1450 1450
E5-02 PM Motor Rated Power (kW) kW 75.00 90.00 110.00 132.00
E5-03
PM Motor Rated Current
(FLA)
A 124.0 153.1 186.5 226.0
E5-04 PM Motor Pole Count - 6 6 6 6