Parameter List
10
10.22 Parameters Changed by PM Motor Code Selection
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual 657
No. Name Unit Motor Code (setting value of E5-01)
E1-06 Base Frequency Hz 57.5 57.5 57.5 57.5 57.5 57.5 57.5 57.5
E1-09
Minimum Output
Frequency
Hz 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9
C5-17 Motor Inertia kgm
2
0.0017 0.0023 0.0083 0.0136 0.0171 0.027 0.046 0.055
L3-24
*1
Motor Accel Time
for Inertia Cal
s 0.062 0.044 0.080 0.090 0.067 0.072 0.088 0.073
n5-02
Motor
Acceleration Time
s 0.062 0.044 0.080 0.090 0.067 0.072 0.088 0.073
n8-49
d-Axis Cur
forHighEfficiency
Cont
% -8.8 -9.9 -9.3 -10.0 -17.7 -12.3 -15.3 -13.9
*1 Default settings vary depending on the setting of o2-04 (Drive Model Selection).
Table 10.17 SSR1 Series Motor Code Setting for Specification of 200 V at 1150 min
-1
(r/min)
No. Name Unit Motor Code (setting value of E5-01)
E5-01
PM Motor Code
Selection
- 140E 140F 1410 1412 1413 1414
Voltage Class V 200 200 200 200 200 200
Capacity kW 15 18 22 30 37 45
Motor Rotation Speed min
-1
1150 1150 1150 1150 1150 1150
E5-02
PM Motor Rated
Power (kW)
kW 15 18.50 22.00 30.00 37.00 45.00
E5-03
PM Motor Rated
Current (FLA)
A 55.6 63.5 74.4 104.2 129.6 154.2
E5-04 PM Motor Pole Count - 6 6 6 6 6 6
E5-05
PM Motor Resistance
(ohms/phase)
Ω 0.084 0.066 0.048 0.035 0.023 0.016
E5-06
PM d-axis Inductance
(mH/phase)
mH 3.83 3.33 2.38 2.04 1.53 1.16
E5-07
PM q-axis Inductance
(mH/phase)
mH 4.65 4.50 3.15 2.86 2.27 1.54
E5-09
PM Back-EMF Vpeak
(mV/(rad/s))
mVs/rad 372.1 421.3 410.9 436.1 428.8 433.3
E5-24
PM Motor Induced
Voltage Constant 2
(Ke)
mV/(r/
min)
0.0 0.0 0.0 0.0 0.0 0.0
E1-04
Maximum Output
Frequency
Hz 57.5 57.5 57.5 57.5 57.5 57.5
E1-05
Maximum Output
Voltage
V 190.0 190.0 190.0 190.0 190.0 190.0
E1-06 Base Frequency Hz 57.5 57.5 57.5 57.5 57.5 57.5
E1-09
Minimum Output
Frequency
Hz 2.9 2.9 2.9 2.9 2.9 2.9
C5-17 Motor Inertia kgm
2
0.064 0.116 0.140 0.259 0.312 0.418
L3-24
*1
Motor Accel Time for
Inertia Cal
s 0.062 0.091 0.092 0.125 0.122 0.135
n5-02
Motor Acceleration
Time
s 0.062 0.091 0.092 0.125 0.122 0.135
n8-49
d-Axis Cur
forHighEfficiencyCont
% -14.4 -17.9 -15.9 -17.9 -20.1 -13.7
*1 Default settings vary depending on the setting of o2-04 (Drive Model Selection).