10.22 Parameters Changed by PM Motor Code Selection
658 YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
Table 10.18 SSR1 Series Motor Code Setting for Specification of 400 V at 1150 min
-1
(r/min)
No. Name Unit Motor Code (setting value of E5-01)
E5-01
PM Motor Code
Selection
- 1432 1433 1435 1436 1438 143A 143B 143D
Voltage Class V 400 400 400 400 400 400 400 400
Capacity kW 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11
Motor Rotation
Speed
min
-1
1150 1150 1150 1150 1150 1150 1150 1150
E5-02
PM Motor Rated
Power (kW)
kW 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11.0
E5-03
PM Motor Rated
Current (FLA)
A 0.94 1.51 3.00 4.43 7.08 10.10 13.33 19.9
E5-04
PM Motor Pole
Count
- 6 6 6 6 6 6 6 6
E5-05
PM Motor
Resistance (ohms/
phase)
Ω 19.320 10.800 4.456 2.044 1.483 1.215 0.660 0.443
E5-06
PM d-axis
Inductance (mH/
phase)
mH 194.70 129.20 76.88 48.60 37.58 44.54 26.36 19.10
E5-07
PM q-axis
Inductance (mH/
phase)
mH 252.84 160.90 97.52 61.40 47.65 56.26 34.20 24.67
E5-09
PM Back-EMF
Vpeak (mV/(rad/
s))
mVs/rad 640.9 654.1 728.8 688.9 702.0 861.5 783.0 762.2
E5-24
PM Motor
Induced Voltage
Constant 2 (Ke)
mV/(r/
min)
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
E1-04
Maximum Output
Frequency
Hz 57.5 57.5 57.5 57.5 57.5 57.5 57.5 57.5
E1-05
Maximum Output
Voltage
V 380.0 380.0 380.0 380.0 380.0 380.0 380.0 380.0
E1-06 Base Frequency Hz 57.5 57.5 57.5 57.5 57.5 57.5 57.5 57.5
E1-09
Minimum Output
Frequency
Hz 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9
C5-17 Motor Inertia kgm
2
0.0017 0.0023 0.0083 0.0136 0.0171 0.027 0.046 0.055
L3-24
*1
Motor Accel Time
for Inertia Cal
s 0.062 0.044 0.080 0.090 0.067 0.072 0.088 0.073
n5-02
Motor
Acceleration Time
s 0.062 0.044 0.080 0.090 0.067 0.072 0.088 0.073
n8-49
d-Axis Cur
forHighEfficiency
Cont
% -8.8 -9.9 -9.3 -10.0 -12.8 -12.3 -15.3 -16.7
*1 Default settings vary depending on the setting of o2-04 (Drive Model Selection).
Table 10.19 SSR1 Series Motor Code Setting for Specification of 400 V at 1150 min
-1
(r/min)
No. Name Unit Motor Code (setting value of E5-01)
E5-01
PM Motor Code
Selection
- 143E 143F 1440 1442 1443 1444
Voltage Class V 400 400 400 400 400 400
Capacity kW 15 18 22 30 37 45
Motor Rotation Speed min
-1
1150 1150 1150 1150 1150 1150
E5-02
PM Motor Rated
Power (kW)
kW 15 18.50 22.00 30.00 37.00 45.00
E5-03
PM Motor Rated
Current (FLA)
A 27.8 31.8 37.2 52.1 64.8 76.6