Parameter Details
11
11.8 H: Terminal Functions
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual 887
Table 11.64 MFDO Terminals Default Function Settings
No. Name Default Setting Function
H2-01 Term M1-M2 Function Selection 0 During Run
H2-02 Term M3-M4 Function Selection 1 Zero Speed
H2-03 Terminal M5-M6 Function Select 2 Speed Agree 1
Refer to Table 11.65 to set H2-xx [MFDO Function Select].
Table 11.65 MFDO Setting Value
Setting Value Function
0 During Run
1 Zero Speed
2 Speed Agree 1
3 User-Set Speed Agree 1
4 Frequency Detection 1
5 Frequency Detection 2
6 Drive Ready
7 DC Bus Undervoltage
8 During Baseblock (N.O.)
9
Frequency Reference from
Keypad
A Run Command from Keypad
B Torque Detection 1 (N.O.)
C Frequency Reference Loss
D Braking Resistor Fault
E Fault
F
*1
Not Used
10 Alarm
11 Fault Reset Command Active
12 Timer Output
13 Speed Agree 2
14 User-Set Speed Agree 2
15 Frequency Detection 3
16 Frequency Detection 4
17 Torque Detection 1 (N.C.)
18 Torque Detection 2 (N.O.)
19 Torque Detection 2 (N.C.)
1A During Reverse
1B During Baseblock (N.C.)
1C Motor 2 Selected
1D During Regeneration
1E Executing Auto-Restart
1F Motor Overload Alarm (oL1)
20 Drive Overheat Pre-Alarm (oH)
21 Safe Torque OFF
Setting Value Function
22
Mechanical Weakening
Detection
2F Maintenance Notification
30 During Torque Limit
31 During Speed Limit
32 In Speed Limit During Trq Ctrl
33 Zero Servo Complete
37 During Frequency Output
38 Drive Enabled
39 Watt Hour Pulse Output
3C LOCAL Control Selected
3D During Speed Search
3E PID Feedback Low
3F PID Feedback High
4A During KEB Ride-Thru
4B During Short Circuit Braking
4C During Fast Stop
4D oH Pre-Alarm Reduction Limit
4E
*2
Braking Transistor Fault (rr)
4F
*2
Braking Resistor Overheat (rH)
60 Internal Cooling Fan Failure
61
Pole Position Detection
Complete
62 Modbus Reg 1 Status Satisfied
63 Modbus Reg 2 Status Satisfied
65 Standby Output
66 Comparator1
67 Comparator2
69 External Power 24V Supply
90 to 93 DWEZ Digital Output 1 to 4
A0 to A7
DWEZ Extended Digital Output
1 to 8
100 to 1A7
Inverse output of 0 to A7
Sets an inverse output of the
function for the MFDO. Put a 1
at the front of the function
setting to set inverse output. For
example, set 138 for inverse
output of 38 [Drive Enabled].
*1 Inverse output is not available.
*2 You cannot set this parameter on models 2169 to 2415 and 4089 to 4675.