EasyManua.ls Logo

Appear TV DC100X - Page 215

Default Icon
352 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
APPEAR AS Confidential 215/352
The following fields are available:
Table Id
For reference only, not configurable
Table Type
For reference only
Mode
Select one of the three or four available modes, depending on the table:
Stop playout is disabled
Pass the table PID will be forwarded from the input, without any
modification. This means that tables sharing a common PID (e.g. SDT A
and SDT O, EIT PF A and EIT PF O, as well as TDT and TOT) must have
common Pass settings to avoid a PID clash with regenerated tables from
the playout carousel. In addition, Pass is not supported for PMT, MGT,
TVCT, and CVCT.
Play the table will be enabled for playout
Playout Interval
Interval in ms between transmissions of each section of the table by the playout
carousel.
Edit
Detail configuration of the values:
The BAT Settings dialog provide access to the ability to define bouquets
The NIT Settings dialog provides access to the Logical Channel
Descriptor’s edit dialog
The TOT Settings dialog provides access to the TOT Local Time Offset
Descriptor’s edit dialog
The following fields are available in NTSC tab:

Table of Contents