APPEAR AS Confidential 192/352
8.4.1.2 Output Redundancy Related Parameters
The Output Redundancy fields are to be used in a system configuration where two IP modules or services are
configured in a redundancy scenario. Refer to Section 12.4 for further details.
The following parameters are available:
Redundancy
Control
Provides the criteria for when to disable the output. Choose from:
All Output TS is disabled if all services are in error
Majority - Output TS is disabled if majority of services (with high priority) are in error
One - Output TS is disabled if one service is in error
None - Output TS is not automatically controlled
Please note that Source IP needs to be enabled and configured correctly if Output Redundancy (OSPF) is enabled.
8.4.1.3 Port Settings for IPv6 output
For IP output modules with IPv6, the Port Settings tab is shown below. When using standard
IPv6 address syntax (128 bits, ‘:’ instead of.’), the GUI will interpret the address as an IPv6 address.
8.4.2 CLONED IP OUTPUT MODULE
The Cloned IP Output module has two physical data ports which both contain the same output represented by
one internal port. Service configuration is performed to the internal data port, and the same service is then
output on both physical data ports.