The following Output Port Redundancy options parameters are available:
Enable output Redundancy
Option to Enable Redundancy on the port.
Redundancy Control
Choose one of the following options:
All The port is signaled to be faulty if all of the outgoing services are
faulty
Majority The port is signaled to be faulty if the majority of the outgoing
services are faulty.
One The port is signaled to be faulty if one of the outgoing services are
faulty
12.3.2 IP OUTPUT REDUNDANCY
The Appear always-on” intelligent redundancy software is a seamless integration between broadcast
equipment and IP networks; providing unmatched reliability of service up-time using the minimum amount of
operating resources possible.
The IP output redundancy functionality makes it possible to have multiple units with IP output modules
multicasting the same services and letting the network handle data loss.
By adding one or more redundant units with IP output modules, service outage may be prevented; given the
error is an isolated one.