13.1.7 ROOT CAUSE FILTER
The root cause filter removes alarms which are caused by alarms earlier in the streams, hence eliminating
distracting alarms. It is turned on and off in the Alarm Setup page.
13.1.8 MONITORING
13.1.8.1 Scrambled Input
Raise alarm for scrambled inputs in IP input ports in below of following condition selected by user.
These are the following options supported:
Off
Never raise the alarm
Any input PID
Raise alarm if any of the PIDs are scrambled at the input
Routed PID only
Rise alarm if any of the PIDs are scrambled at the input
13.1.8.2 PID Status Timeout
This option allows you to specify the timeout for the ā€˜PID missing’ alar in seconds.