5.3 MANUAL PSI
In case the input PSI information is not available, a predefinition of the PSI may be necessary in order to configure
a service that is occasionally available. This could be used, for instance, to predefine some services for dynamic
VOD usage or to signal a STB upgrade PID.
5.3.1 DEFINING A SERVICE (PMT)
In the Manual PSI node, select Define Service from the pull down menu and enter the appropriate slot and port
values matching the incoming stream. Once, theAdd button is clicked the following information is displayed:
Service Id
Service ID for the manual service
PCR PID
PCR PID for the manual service
PMT PID
PMT PID for the manual service
Type
You can here add multiple components and select one of the following component types:
Video (MPEG-2)
H264
Audio (MPEG-2 audio)
AAC
AC-3
Private Sections
PES Private
Manual
PID
PID number for the component
Properties
Additional information for the component, if necessary.