System Products 145
© 2020, ATEÏS. All rights reserved.
Delete: To remove selected text from About text list.
URC-150AS Settings-Global Parameters Tab
The URC-150AS settings of controlling the global parameters like changing master/sub presets.
Users are allowed to create arbitrary number of items until reach the memory limitation which
displayed on the bottom of window.
Add/Delete: Add/Delete a item in URC-150AS for controlling global parameters.
Item: Index of the item.
Label: Display text for the item.
Control Type: Specify which type of global parameter is going to control. Available types list
below:
o Preset Selector: To change master/sub presets.
Assign Right: To specify the item is belong to first layer or protected layer.
Assigned: Indicate the number of presets are selected for change. There is an ellipsis button
on the right of grid cell, click it to open the window for preset selection.
o Check boxes for selection of master/sub presets to be linked to the item.
o Check All button to select all master/sub presets.
o Uncheck All button to de-select all master/sub presets.
o OK button to confirm settings and close window.
o Cancel to discard the modification of settings and close window.
URC-150AS Settings-Sub-preset and Parameters Tab
This tab is for the sub-preset and parameter control using items in URC-150AS.
Function Settings