IDA8 Global-Net User Manual292
© 2020, ATEÏS. All rights reserved.
STX
Data Section
STX
Pnnnnvvv
nnnn = function name (fixed 4 length)
vvvv = value (unfixed)
5. Ethernet Reset Command
Command string = N
STX
Data Section
STX
N
EXT
CS
CR
STX
Data Section
STX
N
EXT
CR
Reset Value
IP Address
192,168,100,230
Sub Mask
255,255,255,0
Gateway
192,168,100,254
Receive Port
19760
6. AutoReply Control Command
Command string =Bnnnnf
STX
Data Section
STX
Bnnnnf
EXT
CS
CR
STX
Data Section
STX
Pnnnnvvv
EXT
CR
nnnn = function name (fixed 4 length)
f = flag (unfixed)
0
End
1
Start
Answer is always Rnnnnvvvv (Reply Read Para. Com.)
7. Firmwave Version Read
Command string = O
STX
Data Section
STX
0
EXT
CS
CR
STX
Data Section
STX
0
EXT
CR
Answer is always Oaaaa-bbbb-cccc-dddd (Reply FirmWave Version Com.)
aaaa = firmwave version 1
bbbb = firmwave version 2
cccc = firmwave version 3
dddd = firmwave version 4
8. Messenger Fault Read